Air Solutions — Air Con Systems
Downloads

MR SLIM · DUCTED

PEY Series · 60 Class

PEY-(Z)M60GAG-AE

More room for your ideas. Cooling kept out of sight.

  • Capacity range: 15.00–17.60 kW
  • Ceiling-concealed indoor unit
  • R32 inverter · Cooling Only
  • 400 mm-high unit
  • ZM60 static pressure: 50 / 100 / 150 Pa
  • Single- and three-phase options

The PEY-(Z)M60GAG-AE range brings ceiling-concealed R32 inverter cooling to larger interiors. Choose PEY-ZM60GAG-AE with 15.00 kW rated cooling or PEY-M60GAG-AE with 17.60 kW, each paired with its matching single- or three-phase outdoor unit. Air reaches the room through discreet grilles while the indoor unit stays above the finished ceiling.

COMFORT FOR YOUR BUSINESS

Cooling built into your plans.

Coordinate the air outlets with your interior, match the ductwork to the airflow requirement and consider the inlet arrangement from the start. The 60-class PEY range gives larger spaces a concealed cooling solution.

Restaurant with discreet linear air vents and all indoor air-conditioning equipment concealed above the ceiling

Keep the interior in focus.

From restaurants to generous residential interiors, ducted cooling lets your room’s design take centre stage. The PEY-(Z)M60GAG unit sits above the finished ceiling, leaving only the air grilles in view. Its 400 mm body height needs to be considered alongside ductwork, drainage and service access when planning the ceiling space.

Open office and adjoining meeting room with ceiling air grilles integrated into the finished interior

Airflow matched to the layout.

A well-designed duct network brings air to the areas that need it. The PEY-ZM60GAG offers external static-pressure settings of 50, 100 and 150 Pa, giving the installer flexibility to match the ducts and outlets. The published 60-class indoor airflow spans 48.0–60.0 m³/min; the final arrangement should be designed around the space and its cooling load.

Illustrative bedroom and sitting area with discreet ceiling vents and no exposed indoor air-conditioning unit

Thoughtful planning for quieter rooms.

In a bedroom or another space where sound matters, the inlet arrangement is part of the comfort plan. The catalogue recommends a rear air inlet because it produces less noise than a bottom inlet. Coordinating the return-air path, grilles and service access helps the concealed installation work with the room from the outset.

Send your floor plan, room use and any cooling-load assessment. We can compare indoor formats, model combinations and controller options.

Talk to Air Solutions

A LITTLE MORE GUIDANCE

Frequently asked
questions.

Helpful answers for your next commercial project.

Which models does this page cover?

PEY-ZM60GAG-AE and PEY-M60GAG-AE. Their rated T1 cooling capacities are 15.00 and 17.60 kW respectively. Each has a matching single- and three-phase outdoor combination shown in the specifications.

Will the indoor unit be visible in the room?

No. The indoor unit is installed above the finished ceiling and connects to room air grilles through ductwork. The Overview images show illustrative finished interiors, not technical installation diagrams.

How much ceiling space is needed?

The 60-class unit is 400 mm high, 1400 mm wide and 634 mm deep. Ceiling-space planning must also allow for suspension, ductwork, insulation, condensate drainage and service access; the body height alone is not the required installation clearance.

What static-pressure settings are listed?

The PEY-ZM60GAG feature table lists 50, 100 and 150 Pa. Both models’ specification table uses 50 Pa as its rating. Confirm the setting options for the exact PEY-M60GAG combination with the supplier.

Does this range include Internal Dry Mode?

The supplied catalogue specifies Internal Dry Mode for PEY-ZM18/24/30/36/45JAG. It does not list that feature for PEY-(Z)M60GAG, so it is not included in this page’s feature list.

How far away can the outdoor unit be installed?

The catalogue lists up to 55 m of piping and a maximum height difference of 30 m for these combinations. The installer must also follow the pipe sizing, refrigerant and installation requirements.

Are controls and the drain pump included?

The catalogue marks the controllers and drain pump as optional. A wireless controller also needs a separate signal receiver. Confirm the selected controls, accessories and package contents before ordering.

LET’S PLAN YOUR NEXT STEP

Your business.
Your comfort.

Send your floor plan, room use and any cooling-load assessment. We can compare indoor formats, model combinations and controller options.

Discuss your requirements
← Back to the light-commercial rangeManufacturer reference (opens in a new tab)