Capacity that grows with the building.
Choose a single outdoor module or a catalogued combination to suit the load. Standard and high-efficiency families provide different capacity and efficiency options for the project.


Recreated Y Series family view. Equipment appearance and combination vary by selected model.
CITY MULTI · HEAT PUMP
PUHY-P / PUHY-EP
Cooling and heating for larger buildings. Explore standard PUHY-P and high-efficiency PUHY-EP combinations, with individually controlled indoor spaces and a shared system operating mode.
THE Y SERIES DIFFERENCE
Cooling and heating for larger buildings. Explore standard PUHY-P and high-efficiency PUHY-EP combinations, with individually controlled indoor spaces and a shared system operating mode.
Choose a single outdoor module or a catalogued combination to suit the load. Standard and high-efficiency families provide different capacity and efficiency options for the project.
Compatible indoor units can be controlled room by room. Depending on the outdoor model, the range supports up to 50 connected indoor units and a connected capacity ratio of 50–130%.
The YKD range allows cooling operation up to a 52°C outdoor intake temperature. Fan control and selectable operating modes support performance in hot conditions; capacity varies with ambient temperature and the installation.
ENGINEERING FOR YOUR BUILDING
Explore the equipment and operating options described in the regional City Multi catalogue.
Mitsubishi Electric’s inverter scroll compressor adjusts its output to the system load. The YKD design includes engineering changes intended to improve part-load operation.
Fixed and automatic-shift settings can raise the refrigerant evaporating temperature when suitable for the load. The installer selects the setting, considering cooling capacity and humidity control.
The specified outdoor operating range extends to 52°C. Cooling capacity and sound level change at high ambient temperatures; system selection should use the applicable performance data.
A selectable fan-speed setting helps support cooling capacity in hot conditions. This setting can increase operating noise and should suit the installation.
An optional operating setting raises compressor speed during the first 30 minutes after cooling starts, helping establish comfortable conditions sooner.
Adjustable low-noise operation limits compressor frequency and outdoor fan speed. Available cooling or heating capacity also falls, so this mode is best selected with the load in mind.
The range allows up to 1,000 m of total refrigerant piping under the catalogue’s conditions. P1400–P1500 systems are limited to 800 m; other length and height restrictions also apply.
Compare the PUHY-P and PUHY-EP families using their nominal capacities, power inputs and model-specific efficiency figures.
COMPARE THE MODELS
Choose a model to see its published capacity and operating data. Figures below follow catalogue CM26ME-E, September 2026.
| Model | PUHY-P200YKD1 (−BS option listed) |
|---|---|
| Operation | Heat pump — cooling or heating |
| Refrigerant | R410A |
| Power supply | 3-phase, 4-wire 380–400–415 V, 50/60 Hz |
| Nominal cooling capacity | 22.5 kW |
| Nominal cooling power input | 4.50 kW |
| Cooling EER | 5.00 kW/kW |
| T3 cooling capacity (46°C outdoors) | 20.4 kW |
| Nominal heating capacity | 22.4 kW |
| Nominal heating power input | 5.05 kW |
| Heating COP | 4.43 kW/kW |
| Outdoor operating range — cooling | −5 to 52°C D.B. |
| Outdoor operating range — heating | −20 to 15.5°C W.B. |
| Maximum connected indoor units | 17 |
| Connected indoor capacity | 50–130% of outdoor capacity |
| Sound pressure — cooling | 57 dB(A) |
Nominal cooling: 27°C D.B. / 19°C W.B. indoors and 35°C D.B. outdoors. T3 cooling, where shown: 29°C D.B. / 19°C W.B. indoors and 46°C D.B. / 24°C W.B. outdoors. Nominal heating: 20°C D.B. indoors and 7°C D.B. / 6°C W.B. outdoors. Ratings use 7.5 m piping and no level difference. D.B. means dry bulb; W.B. means wet bulb.
Sound levels are measured in an anechoic room. Actual capacity and sound vary with conditions and installation. Our team can help confirm complete dimensions, piping limits, variant weights and operating restrictions for your selected model.
| Model | Cooling (kW) | Heating (kW) | Cooling input (kW) | EER (kW/kW) | Max. indoor units |
|---|---|---|---|---|---|
| 22.5 | 22.4 | 4.50 | 5.00 | 17 | |
| 28.2 | 28.0 | 5.92 | 4.76 | 21 | |
| 33.6 | 33.5 | 7.61 | 4.41 | 26 | |
| 40.0 | 40.0 | 9.59 | 4.17 | 30 | |
| 44.5 | 45.0 | 11.99 | 3.71 | 34 | |
| 47.0 | 48.0 | 12.93 | 3.63 | 39 | |
| 55.0 | 55.0 | 14.07 | 3.90 | 43 | |
| 63.0 | 63.0 | 14.25 | 4.42 | 47 | |
| 68.0 | 68.0 | 15.34 | 4.43 | 50 | |
| 73.0 | 73.0 | 17.80 | 4.10 | 50 | |
| 76.0 | 76.0 | 19.24 | 3.95 | 50 | |
| 81.5 | 81.5 | 21.39 | 3.81 | 50 | |
| 90.0 | 90.0 | 25.56 | 3.52 | 50 | |
| 93.0 | 93.0 | 27.27 | 3.41 | 50 | |
| 96.0 | 96.0 | 29.00 | 3.31 | 50 | |
| 103.0 | 103.0 | 31.30 | 3.29 | 50 | |
| 110.0 | 110.0 | 33.63 | 3.27 | 50 | |
| 115.0 | 115.0 | 29.26 | 3.93 | 50 | |
| 122.0 | 121.5 | 30.96 | 3.94 | 50 | |
| 130.0 | 130.0 | 34.90 | 3.72 | 50 | |
| 135.0 | 135.0 | 38.35 | 3.52 | 50 | |
| 138.0 | 138.0 | 40.00 | 3.45 | 50 | |
| 141.0 | 141.0 | 41.83 | 3.37 | 50 | |
| 144.0 | 144.0 | 43.63 | 3.30 | 50 | |
| 151.0 | 151.0 | 45.89 | 3.29 | 50 | |
| 158.0 | 158.0 | 48.17 | 3.28 | 50 | |
| 165.0 | 165.0 | 50.45 | 3.27 | 50 |
Model codes are shown in their standard form. The catalogue also lists optional −BS versions; refer to the original tables for variant details.
KEEP THE DETAILS CLOSE
Refer to the manufacturer’s tables for complete dimensions, piping, electrical requirements and model-specific notes.
YOUR PROJECT, CONSIDERED
We can help confirm model availability, indoor-unit compatibility and the design requirements for your building.