One outdoor system. More possibilities.
Connect compatible indoor units in several rooms and control those spaces individually. A choice of indoor styles helps the system fit the building, from residential interiors to smaller workplaces.


Recreated S Series family view. Equipment appearance and combination vary by selected model.
CITY MULTI · COOLING ONLY
PUMY-CP
Dedicated cooling for homes and smaller commercial spaces, with single-phase and three-phase models and rated capacities from 11.2 to 33.5 kW.
THE S SERIES DIFFERENCE
Dedicated cooling for homes and smaller commercial spaces, with single-phase and three-phase models and rated capacities from 11.2 to 33.5 kW.
Connect compatible indoor units in several rooms and control those spaces individually. A choice of indoor styles helps the system fit the building, from residential interiors to smaller workplaces.
The CP100–140 units stand 981 mm high. Larger twin-fan models extend the range, so you can choose equipment around the cooling load and the space available outdoors.
The catalogue specifies cooling operation at outdoor temperatures from 10 to 52°C. Rated capacity is measured at defined test conditions, so high-temperature performance must be considered when sizing the system.
ENGINEERING FOR YOUR BUILDING
Explore the equipment and operating options described in the regional City Multi catalogue.
Compressor output adjusts to the combined demand of the connected indoor units, helping the system respond as room loads change.
Single-fan and twin-fan unit formats are available across the S Series. Select the dimensions and airflow arrangement around the installation.
The largest CP300 model can connect up to 29 indoor units. The allowable number and total connected capacity depend on the outdoor model.
A two-pipe refrigerant system links the outdoor equipment to compatible indoor units. Piping distances, branch arrangements and height differences must follow the selected model’s design limits.
Cooling operation is specified up to 52°C outdoors. Check corrected capacity at the design temperature and ensure the installation has suitable ventilation.
Applicable CP V(Y)KM models offer three quiet settings in addition to normal operation. An optional PAC-SC36NA-E interface is required, and available capacity reduces with the selected setting.
COMPARE THE MODELS
Choose a model to see its published capacity and operating data. Figures below follow catalogue CM26ME-E, September 2026.
| Model | PUMY-CP100VKM2-U (−BS option listed) |
|---|---|
| Operation | Cooling Only |
| Refrigerant | R410A |
| Power supply | 1-phase 220–230–240 V, 50 Hz; 220 V, 60 Hz |
| Nominal cooling capacity | 11.2 kW |
| Nominal cooling power input | 2.80 kW |
| Cooling EER | 4.00 kW/kW |
| T3 cooling capacity (46°C outdoors) | 9.0 kW |
| Outdoor operating range — cooling | 10 to 52°C D.B. |
| Maximum connected indoor units | 7 |
| Connected indoor capacity | 50–150% (maximum 130% in simultaneous operation) |
| Sound pressure — cooling | 52 dB(A) |
| Dimensions H × W × D | 981 × 1,050 × 330 (+25) mm |
| Net weight — standard version | 86 kg |
Nominal cooling: 27°C D.B. / 19°C W.B. indoors and 35°C D.B. outdoors. T3 cooling, where shown: 29°C D.B. / 19°C W.B. indoors and 46°C D.B. / 24°C W.B. outdoors. Ratings use 7.5 m piping and no level difference. D.B. means dry bulb; W.B. means wet bulb.
Sound levels are measured in an anechoic room. Actual capacity and sound vary with conditions and installation. Our team can help confirm complete dimensions, piping limits, variant weights and operating restrictions for your selected model.
| Model | Cooling (kW) | Cooling input (kW) | EER (kW/kW) | Max. indoor units |
|---|---|---|---|---|
| 11.2 | 2.80 | 4.00 | 7 | |
| 14.0 | 3.84 | 3.65 | 10 | |
| 15.5 | 4.70 | 3.30 | 12 |
Model codes are shown in their standard form. The catalogue also lists optional −BS versions; refer to the original tables for variant details.
KEEP THE DETAILS CLOSE
Refer to the manufacturer’s tables for complete dimensions, piping, electrical requirements and model-specific notes.
YOUR PROJECT, CONSIDERED
We can help confirm model availability, indoor-unit compatibility and the design requirements for your building.