Cooling for every kind of home.
The MS-GS Series provides cooling-only wall-mounted models for homes, townhouses and apartments. Capacities range from 3.5 kW to 9.5 kW. Select capacity using a room load assessment.

01 / 06Indoor unit · view 1
Product images are for illustration.
M SERIES · WALL MOUNTED
MS-GS13-36VF
Everyday comfort.
Thoughtfully selected for your space.
Explore a wall-mounted range with capacities from 3.5 kW to 9.5 kW, supported by personal guidance from Air Solutions.
THE MS-GS DIFFERENCE
From adjustable airflow to thoughtful filtration, the MS-GS Series brings practical cooling features to daily life. Discover the details that help your space feel more inviting.

The MS-GS Series provides cooling-only wall-mounted models for homes, townhouses and apartments. Capacities range from 3.5 kW to 9.5 kW. Select capacity using a room load assessment.

Find the airflow that feels right, from a relaxed afternoon to a busy evening at home. Four fan speeds and automatic fan control help you adjust cooling to your day. Motorised up/down airflow directs air through the room, while GS18/24/30/36 models also offer automatic left/right airflow.

Enjoy cooling comfort with a fresh focus on the air around you. The MS-GS Series includes a Nano Platinum Filter designed to suppress bacteria and mould and help reduce odours. For added filtration, an optional Electrostatic Anti-Allergy Enzyme Filter helps reduce airborne allergens. It’s a thoughtful way to enhance your indoor environment and make the rooms you spend time in feel more inviting.
COMFORT IN THE DETAILS
Explore the key features of the MS-GS Series, then choose a model around the needs of your space.

Boost cooling for faster room comfort.
An energy-saving cooling mode.
Filtration designed to suppress bacteria and mould and reduce odours.
Adjustable airflow, plus automatic fan-speed control according to room conditions.
A motorised horizontal vane distributes air vertically.
Available on GS18/24/30/36 models, which also feature double horizontal vanes.
Schedule when the air conditioner starts and stops.
Resumes operation after a power interruption.
An automatic comfort-control function.
Records operating faults to support servicing.
Lower global-warming potential than R410A.
DC motor technology for the indoor fan.
M SERIES · FIXED SPEED · COOLING ONLY
Compare all five MS-GS models for the UAE, from cooling performance and energy ratings to dimensions, electrical requirements and installation details.
Swipe or scroll to compare all five models.
| Indoor unit | MS-GS13VF | MS-GS18VF | MS-GS24VF | MS-GS30VF | MS-GS36VF |
|---|---|---|---|---|---|
| System details | |||||
| Outdoor unit | MU-GS13VF | MU-GS18VF | MU-GS24VF | MU-GS30VF | MU-GS36VF |
| Operation | Cooling Only | Cooling Only | Cooling Only | Cooling Only | Cooling Only |
| Power supply (outdoor) (V)Single phase | 220–230–240 | 220–230–240 | 220–230–240 | 220–230–240 | 220–230–240 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 |
| Operating current (A) | 4.4 | 6.5 | 8.7 | 10.3 | 12.6 |
| Cooling performance · T1*Specifications at 230 V | |||||
| Capacity (kW) | 3.500 | 5.200 | 6.700 | 8.200 | 9.500 |
| Capacity (Btu/h) | 11,942 | 17,743 | 22,861 | 27,980 | 32,415 |
| Total input (kW) | 0.995 | 1.475 | 1.900 | 2.330 | 2.700 |
| EER (Btu/h/W) | 12.00 | 12.03 | 12.03 | 12.01 | 12.01 |
| CSPF | 12.76 | 12.76 | 12.76 | 12.76 | 12.76 |
| Cooling performance · T3*Specifications at 230 V | |||||
| Capacity (kW) | 3.300 | 4.700 | 5.920 | 7.034 | 8.215 |
| Capacity (Btu/h) | 11,260 | 16,037 | 20,200 | 24,001 | 28,031 |
| Total input (kW) | 1.310 | 1.865 | 2.350 | 2.790 | 3.260 |
| EER (Btu/h/W) | 8.6 | 8.6 | 8.6 | 8.6 | 8.6 |
| CSPF | 10.54 | 10.51 | 10.51 | 10.47 | 10.47 |
| Indoor unit | |||||
| Power input (rated) (kW) | 0.050 | 0.050 | 0.050 | 0.070 | 0.070 |
| Running current (rated) (A) | 0.39 | 0.42 | 0.40 | 0.61 | 0.61 |
| Dimensions (mm)Height × width × depth | 290 × 799 × 232 | 325 × 1,100 × 238 | 325 × 1,100 × 238 | 365 × 1,170 × 295 | 365 × 1,170 × 295 |
| Net weight (kg) | 9.2 | 14.9 | 14.9 | 20 | 20 |
| Air volume (m³/min)Lo / Med / Hi / SHi | 7.1 – 9.9 – 12.6 – 14.8 | 12.5 – 14.9 – 17.1 – 22.0 | 12.5 – 14.3 – 17.1 – 22.4 | 15.0 – 19.0 – 23.0 – 25.0 | 15.4 – 19.1 – 23.2 – 25.4 |
| Sound level (SPL) (dB(A))Lo / Med / Hi / SHi | 29 – 37 – 42 – 48 | 35 – 41 – 46 – 53 | 37 – 42 – 47 – 53 | 37 – 42 – 47 – 53 | 40 – 45 – 50 – 53 |
| Outdoor unit | |||||
| Dimensions (mm)Height × width × depth | 525 × 718 × 255 | 525 × 718 × 255 | 880 × 840 × 330 | 880 × 840 × 330 | 1,258 × 870 × 295 |
| Net weight (kg) | 33.5 | 34.0 | 58.5 | 66.5 | 81.5 |
| Air volume (m³/min) | 31.7 | 32.4 | 52.0 | 52.0 | 85.8 |
| Sound level (SPL) (dB(A)) | 52 | 53 | 56 | 56 | 57 |
| Breaker size (A) | 10 | 15 | 20 | 20 | 25 |
| Piping | |||||
| Piping diameter (inch)Liquid / gas | 1/4 – 3/8 | 1/4 – 1/2 | 1/4 – 5/8 | 1/4 – 5/8 | 3/8 – 3/4 |
| Maximum piping length (m)Outdoor–indoor | 20 | 30 | 30 | 30 | 30 |
| Maximum height difference (m)Outdoor–indoor | 10 | 10 | 10 | 10 | 15 |
| Operating range | |||||
| Guaranteed operating range (°C)Outdoor | 21 – 46 | 21 – 46 | 21 – 46 | 21 – 46 | 21 – 46 |
USEFUL INFORMATION
Download the MS-GS overview
or the room planning guide.
A LITTLE MORE GUIDANCE
Helpful answers as you explore
your next air conditioning system.
Room dimensions, ceiling height, glazing, sunlight and occupancy all affect the capacity needed. Share these details with Air Solutions and we can help you compare the available options.
Choose a position that allows air to circulate through the room and provides access for cleaning and servicing. A qualified installer can assess the wall, drainage and connection route to the outdoor unit.
Think about the indoor and outdoor locations, electrical supply, drainage and access. Our team can discuss the project with you and help identify what your installer needs to assess.
Follow the instructions supplied with your specific model for filter cleaning and routine care. Arrange servicing with a qualified technician, and ask our team if you need help finding the correct documentation.
Yes. Tell us about your space and requirements. We can help you compare capacities, discuss installation planning and confirm the available configuration for your project.
LET’S FIND YOUR FIT
Send your room dimensions, ceiling height, glazing and sun exposure. We can help compare capacities and indoor/outdoor combinations.